A 78-year-old presbyope with LASIK and RK scars, a traumatic corneal scar, pseudophakia and decompensated esophoria reached 20/20 at distance and near, without diplopia or discomfort, using an impression-based scleral lens with prism and pupil-centered EDOF multifocal optics.

At a glance

Patient

78-year-old man: LASIK and RK scars OU, corneal scar OD from injury, PCIOL OU, dry eye, decompensated esophoria

Problem

Progressive spectacles with base-out prism gave reduced distance acuity OD and did not resolve his visual needs

Lens

EyePrintPro impression-based scleral lens with prism; OVITZ-measured pupil center used to decenter an EDOF multifocal optic (+1.50 add)

Result

20/20 OU at distance and near, without diplopia or discomfort

Methods

EyePrint impressions were taken OU, and a diagnostic ZenLens was used for over-refraction. Single-vision distance EyePrintPro lenses were ordered with orientation markings. The OVITZ aberrometer measured the pupil centers relative to the lens, and the lab offset the optic to align with the pupil before applying the EDOF multifocal design.

Results

CorrectionDistance VA ODDistance VA OSPrism
Habitual progressive spectacles20/40−120/25Base-out prism
Diagnostic scleral lens20/2520/20None
Single-vision EyePrintPro20/2020/206 pd BO total, base-up OS
OVITZ decentered EDOF multifocal20/2020/206 pd BO total, base-up OS

The poster reports the habitual and ordered prism amounts inconsistently in text and table; this page shows the final configuration only. HOA RMS and pupil size are not reported.

With the decentered EDOF multifocal lens, the patient achieved 20/20 at distance and near without diplopia or discomfort, which he had not achieved with progressive prism spectacles.

Clinical takeaways from the authors

  1. Center the optic on the pupil. Precise optical centration over the pupil may reduce visual disturbances from multifocal or prismatic optics and limit interference from corneal irregularities.
  2. Lower adds can work. Precise centration may help lower-add multifocal designs succeed in aging patients.
  3. Prism and multifocal optics can be combined in one scleral lens to address binocular, distance and near needs together.

Limitations

Single case report; HOA RMS is not reported, and prism values are reported inconsistently on the poster.

Disclosures

Nicolas Brown and Jenny Wong, OD, are affiliated with OVITZ.

Have patients like this?

OVITZ is built for complex eyes. Every wavefront-guided optic is custom-designed by the OVITZ optical team from your xwave measurements, and we review complex cases with you, including post-crosslinking, CAIRS, post-PK, post-refractive surgery and highly irregular corneas. OVITZ optics work with most major scleral lens brands.

Related

Halos or Starbursts After LASIK, PRK or RK? →

For your patients: a plain-language guide you can share

Need Reading Glasses With Your Scleral Lenses? →

For your patients: a plain-language guide you can share

Clinical information notice: This page summarizes a clinical poster for eye care professionals. Individual outcomes vary. It is not a diagnosis or a substitute for evaluation by a qualified eye care professional.