A patient who had given up on scleral lenses because of night glare and ghosting reached 20/15 with a wavefront-guided scleral lens and reported that his visual disturbances resolved.
Patient
31-year-old man with keratoconus, right eye worse than left; corneal crosslinking in the right eye at diagnosis, two years earlier
Problem
Previously failed scleral lenses because of persistent night glare and ghosting, worse in scleral lenses than in spectacles
Lens
ARES scleral lens (Valley Contax, Eugene, OR) with a wavefront-guided optic designed on the OVITZ xwave system
Result
BCVA 20/25 → 20/15; resolution of visual disturbances and better quality of vision in normal and low light
Habitual spectacle acuity was 20/40 OD and 20/20 OS. Over-refraction through a diagnostic scleral lens gave 20/25 OD, but the patient immediately reported worse glare and ghosting. Aberrometry over the lens showed a residual HOA RMS of 0.64 µm at a 7.3 mm pupil, led by secondary coma and spherical aberration.
Orientation dot markings were added to the conventional lens so the correction could be aligned to the patient’s visual axis. The patient was remeasured over the marked lens with the OVITZ xwave, and a wavefront-guided optic was designed from the residual aberrations. Because of the patient’s large pupil, the lens optical zone was increased to 9.5 mm and the HOA optic zone to 7.3 mm.
| Correction | BCVA | HOA RMS, 7.3 mm pupil | HOA RMS, 3 mm pupil |
|---|---|---|---|
| Habitual spectacles | 20/40 | — | — |
| Conventional scleral lens | 20/25 | 0.64 µm | 0.14 µm |
| Wavefront-guided scleral lens | 20/15 | 0.49 µm (−25%) | 0.06 µm (−57%) |
At the last follow-up, the patient had all-day wearing comfort. He reported that his visual disturbances had resolved and that his quality of vision was significantly better in both normal and low light.
Single case. The post-correction HOA RMS at a 7.3 mm pupil was simulated from wavefront data, and the follow-up duration was not reported on the poster.
Nicolas Brown is an OVITZ employee. Jenny Wong, OD, is a consultant to OVITZ.
OVITZ is built for complex eyes. Every wavefront-guided optic is custom-designed by the OVITZ optical team from your xwave measurements, and we review complex cases with you, including post-crosslinking, CAIRS, post-PK and highly irregular corneas. OVITZ optics work with most major scleral lens brands.
Keratoconus: Still Seeing Ghosting or Halos With Scleral Lenses? →
For your patients: a plain-language page you can share
Wavefront-Guided HOA Reduction in Longstanding Scleral Lens Wearers →
Jamie Kuzniar, OD · Elevate Eye Care
Clinical information notice: This page summarizes a clinical poster for eye care professionals. Individual outcomes vary. It is not a diagnosis or a substitute for evaluation by a qualified eye care professional.