Three keratoconus patients who were already successful scleral lens wearers, but still reported ghosting, glare, halos and monocular diplopia, had residual HOA RMS reduced by 35% to 80% after a wavefront-guided optic was added to the same lens platform.
Patients
Three men with keratoconus, aged 35, 37 and 71; long-standing scleral lens wear
Problem
Persistent ghosting, glare, halos and monocular diplopia despite a stable, finalized scleral fit
Lens
Bausch + Lomb Zenlens in all cases, with fiducial markings; wavefront-guided optic designed on the OVITZ xwave
Result
Residual HOA RMS down 35% to 80% per eye; BCVA equal or better in every eye; all three reported better subjective vision
After a stable finalized fit was achieved, fiducial markings were added to each Zenlens (the “standard lens”). The xwave measured the residual HOAs and the precise on-eye position of the lens, and a custom wavefront-guided optic was then added to the lens. All aberrometry is reported at a 5.5 mm pupil.
| Case | Eye | BCVA, standard lens | BCVA, HOA lens | HOA RMS, standard | HOA RMS, HOA lens | Change |
|---|---|---|---|---|---|---|
| 1 · 35 y | OD | 20/30 | 20/25 | 1.58 µm | 0.63 µm | −60% |
| OS | 20/20 | 20/15 | 0.47 µm | 0.30 µm | −35% | |
| 2 · 37 y | OD | 20/30 | 20/30 | 2.12 µm | 0.97 µm | −54% |
| OS | 20/30 | 20/30 | 2.15 µm | 0.93 µm | −57% | |
| 3 · 71 y | OD | 20/40 | 20/20 | 0.70 µm | 0.29 µm | −58% |
| OS | 20/60 | 20/40 | 1.72 µm | 0.34 µm | −80% |
Residual HOA RMS at 5.5 mm pupil
Data note: Case 1 values follow the poster’s narrative text, which is internally consistent. The poster’s summary table for Case 1 lists the starting values in a different order.
Case 2 kept the same 20/30 acuity in both eyes, yet the patient reported significantly better subjective vision with the wavefront-guided lens. Case 3 also had mild nuclear sclerosis in both eyes.
Small case series of three patients without a control group.
Jamie Kuzniar, OD, is a consultant for Bausch + Lomb Specialty Vision. Jenny Wong, OD, and Nicolas Brown are affiliated with OVITZ.
OVITZ is built for complex eyes. Every wavefront-guided optic is custom-designed by the OVITZ optical team from your xwave measurements, and we review complex cases with you, including post-crosslinking, CAIRS, post-PK, post-refractive surgery and highly irregular corneas. OVITZ optics work with most major scleral lens brands.
Keratoconus: Still Seeing Ghosting or Halos With Scleral Lenses? →
For your patients: a plain-language guide you can share
Vision Performance After Reduction of HOAs in Keratoconus →
Alex Bennett, OD & Barry Leonard, OD · Leonard-Bennett Optometry
Reducing Night Glare and Ghosting in a Keratoconus Patient Who Failed Conventional Scleral Lenses →
Clark Chang, OD · Wills Eye Hospital
Clinical information notice: This page summarizes a clinical poster for eye care professionals. Individual outcomes vary. It is not a diagnosis or a substitute for evaluation by a qualified eye care professional.